Agnew · Ductless
A window unit gone, a ductless head in its place
A converted garage living room with no ducts and a window AC that leaked onto the sill. One 12,000 BTU head, a slim condenser on the side wall, the window reglazed.
1 dayOn site
12k BTUCapacity
1 zoneHeads
10 daysPermit to final
Eight frames, one camera
The job, frame by frame.
Converted garage living room in Agnew, camera on the kitchen counter for every frame.
01 · Before
02 · Assess
03 · Remove
04 · Prepare
05 · Install
06 · Connect
07 · Commission
08 · Finished
What went in
Equipment and readings.
- Single-zone inverter heat pump, 12,000 BTU, 22 SEER2
- Wall head mounted high on the shared wall, 3-inch core drilled for the line set
- Condensate pumped to the exterior, line-set cover painted to match
- Window opening patched, insulated and reglazed by our carpenter
- Dedicated 20A circuit from the panel
“Quiet enough that I forget it is on, and the room finally stays warm in January.”